    Floor lighting system

Floor lighting system

Versatile, non-dazzle LED illumination. Depending on the application, area of use and control unit used, this product  takes over the function – among others – of floor lighting, a handset distributor, or also the alarm function in the Out-of-Bed system.

  • Protection type: max. IPX6
  • Equipment options:
    As a handset distributor with 2 floor lighting systems and 13-pole handset socket.
    The version with LSP socket for the Out-of-Bed system is cascadable (i.e. several floor lighting systems can be switched in sequence).

 

    Standard configurations

    Components
    Housing colour light grey RAL 7035 (housing lower part)
    transparent (housing lower part)
    Further data
    Protection type max. IPX6
    Relative humidity 30% – 75%
    Ambient temperature +10°C - +40°C
    Assembly options for flexible assembly on the appliance

    Extra configurations

    Further data
    Equipment options As a handset distributor with 2 floor lighting systems and 13-pole handset socket.
    The version with LSP socket for the Out-of-Bed system is cascadable (i.e. several floor lighting systems can be switched in sequence).

    Out-of-Bed system

    Safety is important for people who are in need of care, especially when patients need protection during the night, and this is why we have developed the Out-of-Bed system.
    As soon as the patient gets out of bed, the floor lighting system is switched on, which allows him or her to move safely around the room.
    After the delay time has expired, the CU 155's potential-free switch contact activates an alarm system, a calling system or a lamp.
    The activation delay can be set individually to 15 or 30 seconds or 10 or 15 minutes.
    Activation and control of the system is possible via the IPROXX 2 Out-of-Bed handset. The handset can be used to switch the system off completely, and to switch the floor lighting on and off manually.
    This system supports the staff and ensures patient safety.

    more »

    Datasheet

    Manuals
    Ident No. Title Language Type  
    63717 UNTERBETTBELEUCHTUNG D Installation instruction  
    64412 UNTERBETTBELEUCHTUNG GB Installation instruction  

    Request 3D cad data: Please contact an office next to you

    Note: Responsibility for DEWERT products when used for specific applications and for adherence to the appropriate guidelines, standards and laws is borne by the manufacturer of the complete system into which DEWERT products are fitted. We accept no liability for the correctness.

    CE declaration of conformity:
    We herewith declare that the actuator described above complies with the basic requirements of EC Guideline 2014/30/EU and EC Guideline 2014/35/EU in terms of its conception and design as well as the version we have placed into circulation. We would be glad to help you in having your end products inspected by certified testing companies such as TÜV, LGA, UL, JET, LNE etc.