GIGAMAT

Designed for extreme loads. This high-performance drive offers approx. 100% more mechanical performance than a conventional MEGAMAT-class drive.

  • Load capacity: max. 10000 N push / max. 7000 N pull
  • Adjustment speed: max. 19.3 mm/sec. *
  • Stroke length: max. 550 mm
  • Equipment options: adjustable gear clevis (only for pull-drives up to max. 1000 N), additional limit switch, potentiometer

 

* depending on drive configuration at constant 24/29 V DC without load

Standard configurations

Performance data
Load capacity max. 10000 N push
max. 7000 N pull
Adjustment speed 1 max. 19.3 mm/sec.
Stroke length max. 550 mm
Fitting dimension (B) 2 210 mm + stroke
Duty cycle 2/18 min. or 10 %, max. 5 switching cycles per minute
Motor voltage maintenance-free 24 V DC motors
Components
Limit switch with micro switch
Stroke pipe clevis drill hole: 10 mm
recess: 5/8 mm
Gear clevis die cast zinc
drill hole: 10 mm
recess: 5/8 mm
Stroke pipe stainless steel
Guidance profile aluminum untreated
Housing colour light grey RAL 7035
Motor connecting line grey, straight, 300 mm, LSP-plug, PVC
grey, straight, 830 mm, LSP-plug, PVC
Further data
Protection type max. IPX6
Protection class III
Relative humidity 30% - 75%
Ambient temperature +10°C - +40°C

Extra configurations

Performance data
Components
Position feedback potentiometer
Clevis adjustable gear clevis (only for pull drives up to max. 1000 N)
Motor connecting line pluggable
Further data
Quick release /
Retracting function 3
mechanical retracting function up to max. 10000 N (only for push drives), special mechanical retracting system for patient lifter
Equipment options additional limit switch

1 depending on drive configuration at constant 24/29 V DC without load
2 see technical drawings
3 Retracting function: The clutch of the lowering function must be open during the entire downward movement.

1 | 2
Type (Fitting dimension 210 mm + Stroke) GIGAMAT 5000 GIGAMAT 7000 GIGAMAT 10000
Max. push / pull force at stroke
0 - 350 mm
5000 / 5000 N 7000 / 7000 N 10000 / 7000 N
Max. push / pull force at stroke
351 - 470 mm
5000 / 5000 N 7000 / 7000 N -
Max. push / pull force at stroke
471 - 550 mm
5000 / 5000 N - -
Adjustment speed 1 up to 19.3 mm/s up to 14.5 mm/s up to 9.6 mm/s

1 depending on drive configuration at constant 24/29 V DC without load

Datasheet

Manuals
Ident No. Title Language Type  
57652 GIGAMAT D Installation instruction  
58717 GIGAMAT GB Installation instruction  

Request 3D cad data: Please contact an office next to you

Note: Responsibility for DEWERT products when used for specific applications and for adherence to the appropriate guidelines, standards and laws is borne by the manufacturer of the complete system into which DEWERT products are fitted. We accept no liability for the correctness.

CE declaration of conformity:
We herewith declare that the actuator described above complies with the basic requirements of EC Guideline 2014/30/EU and EC Guideline 2014/35/EU in terms of its conception and design as well as the version we have placed into circulation. We would be glad to help you in having your end products inspected by certified testing companies such as TÜV, LGA, UL, JET, LNE etc.